JOHNSON FINE ARTS CENTER

Technical Information

Load-in Area | Carpentry | Lighting | Sound | Props (Concert Equipment)
Wardrobe | Management

The Ground Plan and Cross Section of the Johnson Fine Arts Center formatted to print on 8.5x11 paper in landscape mode. You may need to download the free Adobe Acrobat Reader to view (or print) these files.


General Information


Revised: February 20, 2001

ADDRESS Johnson Fine Arts Center Northern State University 1200 S. Jay Street Aberdeen, SD 57401

Booking Information... Contact... Alan LaFave, Dean of Fine Arts 626-2497 Tracy Jurgens 626-2497

Technical Director... Larry Wild, Assistant Professor of Theatre Office: JFAC 124A Address: NSU, Box 728, 1200 S. Jay, Aberdeen SD, 57401 e-mail: wildl@northern.edu Office phone: 605-626-2513 Home phone: 605-226-2658 FAX: 605-626-3022 Box Office... There is no box office in the Johnson Fine Arts Center. Area Hotels... Super 8 (Three in town): Reservation line:1-800-800-8000 Comfort Inn: 1-800-424-6423 Ramkota, Best Western: 605-229-4040 Ramada Inn: 605-225-3600 The Ramada Inn, Comfort Inn, and one of the Super 8 motels is located on East US 12, a second Super 8 is located on West, US 12, and the third Super 8 and the Ramkota is located on North US 281. TAXI SERVICES... Aberdeen Taxi 225-6280 or 225-4554 HANDICAPPED TRANSPORTATION... Ride-Line 225-5044 RESTAURANTS... Mill Stone 229-4015 RG's 226-0316 Perkins 225-9059 Shenanigans 225-6210 (Sports bar) James River Milling (@ Ramkota) HANDICAP ACCESS... JFAC is handicap accessable. The auditorium is wheelchair accessable through both front-of-house (southeast and southwest) entrances. The back stage area is accessable through the northwest entrance. There is a wheelchair lift in the east hallway joining the auditorium area with the backstage area. EMERGENCY NUMBERS... FIRE 911 POLICE 911 AMBULANCE 911 St. Luke's Hospital 626-5000 ROUTINE NUMBERS... Fire 626-7048 Police 626-7911 Ambulance 626-7048 CHIROPRACTOR... Winkler Chiropractic Clinic, 803 S. Main, 225-8288 LAUNDRY... Mercury Cleaners & Laundry, 603 S. Main Street, 225-6370 TRAVEL DIRECTIONS... Northern is located in the south east corner of Aberdeen. Access from the east along US 12 (I 29): Take US 12 to State Street, turn left (south) on State Street at the "BlockBuster Video" corner and head south to 12th Ave. Turn right (west) on 12th. JFAC is the first building on the left (south). Access from the south (Redfield, Huron, Mitchell) along US 281: Take US 281 into the west edge of town. Turn right (east) where US 281 joins US 12. When US 281 turns north at the "Hardee" corner, continue east on US 12 till you reach State Street. Turn right (south) on State Street at the "BlockBuster Video" corner and head south to 12th Ave. Turn right (west) on 12th. JFAC is the first building on the left (south). TIME ZONE... Central time zone.


TOP

LOAD-IN AREA



        Shows are loaded through the Scene Shop (36'x60') located
        directly behind the stage. There are two 9'-9" x 15'-9" loading
        doors between the stage and the shop.  Because of the width 
        of the alley behind the theatre (33') a 40' semi-trailer can
        NOT back up to our loading dock. The loading dock is 42" above
        the level of the roadway.

        A show can also be loaded through the "stage door" on the
        north east side of the building. A 40' semi-trailer can back
        up to this entrance. If this entrance is used, the trailer will
        need to be moved to the north side of the building after the
        production has been loaded into the theatre.


TOP

CARPENTRY



SEATING CAPACITY...
        Maximum capacity: 1004

STAGE DIMENSIONS...
        Proscenium width: 60'
           Standard stage width: 40' (closed down with act curtain)
	Proscenium height: 22'
           Height with house valence gridded: 16'
	Stage depth from plaster line to back wall: 40'
	Depth of apron at center line: 2'
        Width of stage house: 100'
        Height of stage above audience level: 3'-6"
	Distance from first row to front of stage: 18'
        Obstructions: The patchbay (5'x6'6") is located on the down
           stage right proscenium wall, 34' right of the centerline.
        Orchestra pit:
           Width of pit: 54'
           Depth of pit at center line: 13'-8"
           Depth of pit at edges: 8'-4"
           The pit is hydraulic, and will run from stage level to a
              depth of 9'-6" feet.

STAGE FLOOR...
        Color: Black
        Finish: Painted
        Material: Plywood
        Condition: Poor
	There are no lifts, but the floor is trapped
        We have access to a "Morley" floor

HOUSE DRAPERY...
        House curtain           Gold;  Traveler, controlled from SR

ITEM              #        MATERIAL          W x H
------------------------------------------------------------------------
Legs-black        12       commando cloth    9' x 24'
Borders-black      3       duvetyne          48' x 4.5'
Travelers-black    2       velour            60' x 26'
Scrim-black        1       sharkstooth       60' x 28'
Cyclorama          1       muslin            60' x 28'

LINE SET DATA...
        Type: Wire guided, single purchase, counter weight
        Height of grid: 30'
        High trim: Non-electric pipes: 27'
                   Electric pipes: 24'
        Low trim:  5'
        Total number of line sets: 15
        Arbor capacity...
           Non-electric pipes: 968 lbs (4'-8" arbor)
           Electric pipes:     1760 lbs  (7'-8" arbor)
        Available weight:
        Weight sizes: 13 to 44 lbs
           (We have a limited number of "extra" weights)
        Length of pipes...
           Line sets: 1, 2, 5, 6, 9, 10, 13, 14, 15:  60'
           Line sets: 3, 4, 7, 8, 11, 12:             48'
        Diameter of pipes: 1 1/4"
        Location of lock rail: Floor level, stage right
        THERE IS NO LOADING RAIL !!

LINE PLOT...
     -3'-6"   Front edge of stage
        O'      Act curtain. Gold velour, traveler. Control: DR
        1'      Line set #1: Valence (teaser), gold velour
        2'      Line set #2: FIRST ELECTRIC (circuitss on 18" centers)
        3' 
        4'
        5'      Line set #3: Ceiling, Concert Shell
        6'
        7'      Line set #4: First Border
        8'      Line set #5: First Leg, 50' one-way travelertrack
        9'      Line set #6: SECOND ELECTRIC (circuits on 18" centers)
       10'      Center stage black velour traveler, Dead hung
       11'
       12'
       13'
       14'      Line set #7: Ceiling, Concert Shell
       15'      Line set #8: Second Border
       16'      Line set #9: Second Leg
       17' 
       18'      Line set #10: THIRD ELECTRIC (circuits on 24" centers)
       19'
       20'      Line set #11: Ceiling, Concert Shell
       21'
       22'
       23'      Line set #12: Third Border
       24'
       25'
       26'      Line set #13: Third Leg & Black scrim
       27'      Line set #14: FOURTH ELECTRIC  (circuits on 24" centers)
       28'
       29'      Up stage black velour traveler, Dead hung
       30'
       31'
       32'
       33'
       34'
       35'
       36'
       37'      Line set #15: Cyc
       38'
       39'
       40'      BACK WALL OF THEATRE

SHOP AREA...
        Location: Up stage, directly behind the stage
        Access to the stage: Via two 9'-9" x 15' -9" "garage" doors
	The shop contains a radial arm saw, table saw, slop sink.
        Hand tools are available via the NSU Theatre department

STORAGE...
        Touring cases, props, and set pieces may be stored in the
        scene shop are in the hallway behind the stage. Costume
        racks may be stored adjacent to the dressing rooms.


TOP

LIGHTING



POWER...
        1 @ 225 amp, 3 phase, 4 wire, 120/208v  DSR
           (100 amps of this power is available thru a "Company Switch")
        4 @ 20 amp Edison plug circuits on stage and orchestra pit

DIMMERS...
        80- 2.4 kW dual Strand CD80sv dimmer modules (160 circuits)

CONTROL...
        Strand Mantrix MX48
           48 channels; 192 cues (in 4 pages); 48 submasters
        Strand Mantrix MX24
           24 channels; 96 cues (in 4 pages); 24 submasters
        DMX terminals in the Light Booth and DR

HOUSE LIGHTS...
        Manual control from the Light Booth

CIRCUITS...
        Dimmer per circuit, 227- 2.4 Kw circuits

        Location       Circuit numbers
        -------------------------------------------
FOH:    Booth             215-216   2 circuits
        Auditorium        213-214   2 circuits
        Cove              1-34      34 cir on 2' centers

STAGE:  First pipe        36-81     45 cir on 18" centers
        Second pipe       82-127    45 cir on 18" centers
        Third pipe        128-158   30 cir on 2' centers
        Fourth pipe       159-189   30 cir on 2' centers

        Wall pockets      190-212   (DR-UR-URC-ULC-UL-DL)
        Curtain warmers   224-227
        Pit down lites    217-223

        Connectors: 20amp, 3-prong twist lock

CABLE...
        12/3 SO with 20 amp, 3-prong twist lock


FOH POSITIONS...
        Booth           88' throw         10 degrees to the plaster line
        Cove            33' throw         34 degrees to the plaster line
        Side Pipes      40' throw         51 degrees to the center line

INSTRUMENTS...
         #      Lens  FA     Watts    Manuf #              Gel frame
         --------------------------------------------------------------
         4      8x12 /12°    750w     Kliegl 1355/8        10x11"
         6      6x8  /18°    750w     Kliegl 1355/6        6 1/2"
        12      6x12 /29°    750w     _ellipsoidal_        6 1/2"
         2      6x9  /37°    750w     Altman 360Q          7 1/2"
        12      8" Fresnel   1000w    Kliegl               10x11"
        12      6" Fresnel   750w     Kliegl 3508          7"
        18      PAR64/WFL    1000w    AltmanCans           10"
         8      16" Scoops   1000w    Kliegl 3451          18"

        Note: The 6x12 _ellipsoidal_ is a modified K1355 containing
        1- 6x8 step lens and 1- 6x12 plano convex lens.

FOLLOW SPOTS...
        2-   Capitol QuartzFollowSpot     1000w (FEL) Quartz    Light Booth

HARDWARE...
        8      6" 4 way barndoors for Kliegl Fresnels
        8      8" 4 way barndoors for Kliegl Fresnels
        4      10' booms

AVAILABLE COLOR...
        Roscolux R01  02  08  12  18  21  26  33  34  51  55  
        63  67  69  80   87  91  93  114  116  120  121  122  
        123  116

STANDARD HANG...
        Cove:     6x12 _ellipsoidals, 6x8 Kliegl 1355/6s and 6 to 8
                  PAR64/WFLs
        On Stage: 6" and 8" Fresnels, PAR64/WFLs and 12" and 16" Scoops

        Pipe and Cove mounted lamps are left hanging between shows. Floor
        and Boom mounted equipment is struck after each production.


TOP

SOUND



PRODUCTION COMMUNICATION...
        4 station, Clear-Com intercom.
        SL, SR, Sound Booth, Light Booth

SOUND LOCATIONS...
        House mixer is located in the last two rows of the center section
        on a 8'-2" x 2'-8" permanent desk
        150' snake needed to reach the house mix position

        A temporary (8' x 2'6") desk can be installed in the cross
        aisle in the center of the auditorium. A 100' snake will be
        needed to reach from the stage to this position

MIXING CONSOLE...
        1-  SoundCraft Venue II
              24 channel (20: mike level; 4: high level)
              8 group matrix

SPEAKERS...
        Center cluster (located over the fifth row)...
           3- JBL2386 (20x40) horns w/ JBL2446 compression drivers
           2- JBL2385 (40x60) horns w/ JBL2446 compression drivers
           2- JBL MR15 w/ 15" low frequency drivers
        Front fill (located over the third row)...
           4- JBL2152 12" coaxial drivers in Lowell P1210X backboxes

        Stage monitors:
           4-  JBL MR805, 15" 2-way monitor speakers

MICROPHONES...
        4       Sennheiser      MD512       Cardioid
        2       AKG             C 568 EB    "Shotgun"
        5       EV              660         Super cardioid
        4       Telex           FMR-70L     Wireless systems w/ WLM-50
                (6 additional wireless mikes are available through the
                 School of Fine Arts)

PLAYBACK...
        1       C D                     TEAC PPD 435
        1       dual cassette           TEAC PW800R
        1       am/fm receiver          YAMAHA RX-385

SIGNAL PROCESSORS...
        3       Rane GE27               graphic equalizer
                  1 each for the center cluster, front fill, and stage
                  monitor systems

AMPLIFIERS...
        Center cluster...
           1    QSC 1400 (2 channel)     200w RMS /channel    HF horns
           1    QSC 1700 (2 channel)     325w RMS /channel    Bass boxes
        Center fill...
           1    QSC 1400 (2 channel)     200w RMS /channel
        Stage monitor...
           1    QSC 1400 (2 channel)     200w RMS /channel

WIRING...
   Hardwired:   12 mic + 2 monitor jacks on pit
                4 mic + 2 monitor jacks DSL
                4 mic + 2 monitor jacks DSR

HARDWARE...
                 stands    

INFRARED...
     JFAC is not equipped with an infrared system for the hearing impaired.

PAGING SYSTEM...
     There is no paging system in the Johnson Fine Arts Center.

POWER...
     11 @ 20 amp, 120v circuits, Edison plug circuits
        3 on the stage, 2 in the pit, 4 in the house, 2 in the Light Booth


TOP

PROPS


Concert Equipment



ORCHESTRA PIT...
        1 lift- 54' x 13'-8" (@ center line), 8'-4" (@ edge)
             The lift can stop any distance from stage level
             to a maximum depth of 9'-6"

MUSIC...
        Chairs       220  musician chairs, black
        Stands        65  Wenger stands
        Pianos        2-  9' Steinway Concert Grands
                      2-  7' Steinway Grands
                          Permission to use any of the pianos must be
                          granted by the Chairman of the Department of
                          Music

CONCERT SHELL...
        14- 6' Wenger _Fold 'n' Roll_ shell units
        15- 8' Wenger _Overhead (ceiling) panels_ The panels are hung on
        three pipes at 5', 14' and 10' up stage of the Curtain Line.

BAND/CHORAL RISERS...
        Wenger seated choral risers (54' x 24'), four levels...
           Including...
             Elev   Units
           -------------------------------
              8"    5- 4'x6'    2- 4'x8'    2- pie shaped sections
             16"    5- 4'x6'    2- 4'x8'    2- pie shaped sections
             24"    5- 4'x6'    2- 4'x8'    4- pie shaped sections
             32"    1- 4'x6'    3- 4'x8'

        9-  Wenger standing choral risers, 3 levels
        7-  4th (32") level Wenger standing choral risers w/ railings

DANCE FLOOR...
        4 rolls-- 6' x (app) 60'

LECTERNS...
        1-  Speaker's lectern with microphone stand


TOP

WARDROBE



DRESSING ROOMS...
        #- Style          Capacity     Location        Size
        --------------------------------------------------------
        2- Chorus         12ea         Stage right     15' x 19'
        1- Make up room   16           Stage right     10' x 38'

Both dressing rooms have toilets, sinks and hanging racks
Make-up mirrors, and counters are only in the Make-Up room.

WARDROBE AREA...
        Located stage right adjacent to the dressing and make-up rooms                

        Washer*                1 top loading
        Dryer                  1 top loading electric

        Iron, ironing board, and sewing machine may be available thru
        the NSU Theatre department.

        * Companies must provide their own detergent.

CROSSOVER...
        Behind the stage through the back hallway.
        The stage is deep enough that many sets will allow room
                up stage for a cross over.

MONITORS...
        There are no paging monitors or audio and video stage monitors
        to the dressing rooms and/or green room.


TOP

MANAGEMENT



PRODUCTION ROOM...
        No separate office is available.
        Telephones are located in the Technical Director's office
        (JC124A, 605-626-2513), the Theatre Department's office
        (JC128, 605-626-2563), and in the front lobby (605-225-9783).

GREENROOM...
        Located stage right near the dressing rooms and costume shop.
        15'-6" x 14'

VENDING MACHINES...
        Machines located in the west end of the front lobby, provide a
        selection of soft drinks (Pepsi products), snacks, candies, 
        and fruit juices. A soft drink machine is also located in the 
        GreenRoom.

REHEARSAL ROOMS...
        There are no rehearsal rooms in the Johnson Center. In the past,
        both the Theatre classroom (JC129, 21' x 30') and the Choir
        room (JC125, 42' x 60') have been used for rehearsal and
        warm-ups. Both rooms have a tile on concrete floor.

CREWS...
        The Johnson Center is a non-union house.  Crews are predominately
        trained students. 

        A member of the JFAC Technical Staff must be present any time
        the facility is in use.

HANDICAP ACCESS...
        JFAC is handicap accessable. The auditorium is wheelchair
        accessable through both front-of-house (southeast and southwest)
        entrances. The back stage area is accessable through the
        northwest entrance. There is a wheelchair lift in the east
        hallway joining the auditorium area with the backstage area.

POLICIES...
        Smoking is not permitted anywhere in the Center.

        No food or drink is allowed in the Auditorium or Light booth.

        Persons under the influence of alcohol or other drugs will
        not be permitted to work back stage.

        Damages to the premises, equipment or properties of the
        Johnson Fine Arts Center, caused by a member of the
        company's staff will be paid for by the company.


Compiled by Larry Wild, Technical Director